Latest filter report

Recently we received the final test report regarding F96 and F94 filters from Nelson Labs. The result summary (and link to the pdf):

F96 filter
Latex Particle Challenge Final report
NelsonLabs-test-F96-0.1u
Test particle size: 0.1μm
Filtration efficiency %: 99.86

F96 filter
Bacterial Filtration Efficiency.
NelsonLabs-test-F96-BFE-Delta-P
Test particle size: 3 μm
Delta P: 11.4 Pa/cm2
Flow rate: 8 L/min
Filtration efficiency %: 99.9*

F96 filter
Viral Filtration Efficiency (VFE) Final report
NelsonLabs-test-F96-VFE
Test particle size: 3 μm
Filtration efficiency %: 99.9*

F94 filter
Latex Particle Challenge Final report
NelsonLabs-test-F94-0.1u
Test particle size: 0.1μm
Filtration efficiency %: 99.71